High-tech Enterprise Laboratory Diet Fume Purification Equipment Materials Detection Device
1. Product Description
It is designed according to the standard requirement of HJT62-2001. Used for the removal efficiency of diet fume purification equipment, suitable for testing organization and manufacture enterprise testing.
2. Standards
HJT62-2001
3. Technical Parameters
Power supply |
AC380V, 50Hz |
Wind volume range |
2000-20000m³/h |
Oil-smoke producing equipment |
adopts oil-water flow automatic allocation and heating evaporation adjust control system, oil smoke producing volume adjustable, ensure 10min average oil-smoke density less than 5%; test benchmark concentration is 10mg/m³ |
Test through sensor |
micro differential pressure, atmospheric pressure, flow; sampling holes are provided 1.5 times the diameter downstream of pipe fittings such as elbow and variable diameter pipe |
Wind volume adjust system |
manual adjust control damper and converter technique |
Air flue |
designed according to the air hose with diameter 0.6m (can meet the standard required wind speed) |
|
Front and back air flue (include straightaway and curve), purifier interface flange (five specification, other specification customized), air flue materials is stainless steel |
Test room dimensions required |
at least 12mX3.5m |
|
With safety monitor, alarming and state analyze alert function |