IEC60384 High-tech Enterprise Electric Capacity Charging and Discharging Test device
1. Product Description
It is designed according to the standard requirements of IEC384, used to the charging and discharging for restrain power battery disturb used fixed capacitor and ceramic capacitor.
2. Standards
IEC60384
3. Technical Parameters
Power supply |
AC 220V±10% 50Hz |
Output direct voltage |
60-600V, continue adjustable, digital display accuracy ±1.0%. |
Test station |
five, synchronous status |
Five route, each route charging current |
0-1A |
Each station capacitor maximum capacity |
1uF,MAX |
Discharging rate |
100V/μs, error rate: ±15% |
Timer(charging and discharging time) |
0.1-999.9s, accuracy ±0.1s |
Counter |
0-9999999 time |
Accuracy degree |
±1 time |
Over current and over voltage protected, can continuous setting protective value |
Machine inner adjustable setting |
|
Device with oscilloscope output port terminal |
Equipped with |
Test chamber with safety switch, with fire prevent heat resistant observation glass window. |
Structure |
Adopts luxury aluminum alloy floor structure |
|
Users supply oscilloscope |