IEC60884 Fluorescent Lamp Power Load Test/Testing Machine for Electrical Annex
1. Product Description
Fluorescent Lamps Power load counter is designed according to the relevant standard requirements of IEC60884 and IEC60669, UL1054 and relevant IEC standards on the electrical annex breaking capacity and match equipment design in the normal operation.
Matching to the use with the mechanical movements test equipment (such as RH19401 plugs and sockets life tester), for on and off capacity test, breaking capacity test, bend test and the normal operation test and so on.
Install with the casters below the cabinet to convenient the move.
Tester with high-grade PLC control, 7 inch touch screen display interface, the operation of the tester is stable, convenient and practical. In order to convenience the customers to adjust the technical parameters, so we according to the common standard parameters to built nearly 30 kinds of commonly used parameters mode, can be quickly and easily to adjusted the current, power factor and other parameters, even if you are the initial time to operation it, also you accurate and rapid adjustment to the demand parameters.In addition, the tester reserved 10 kinds of custom mode, it can based on your real need to setup, adjust and save the parameters, when you want to used it again, you can be quickly adjusted it to the demand parameters.
Can provide the single-route to all kinds of electrical appliances annex, the voltage can adjustable from 50 to 280V, the current is 1 to 45A, and within 0.3-0.96 power factor of test load and can be used for other household electrical appliances of test load.
Intelligent automatic fitting function: input the standard required test parameter, calculate the V, L, R value by intelligent computing; programmed the hardware of corresponding parameter to preset (no output at preset). Programmed output to the external connection terminal to the sample after regulate the parameter to the require value. Using resistance matrix and inductance matrix to replace manual regulation, varieties of test mode and experienced intelligent digital control system, simplify the operation, and reduce error possibilities and training cost.
2. Standards
IEC60884 and IEC60669,UL1054
3. Technical Parameters
Fluorescent lamp load
Load A |
capacitance is equipped with two groups, one is 70uF and the other is 140uF |
Load B |
capacitance is 7.3uF, inductance is 0.5H |
Without load |
the voltage i s 50V-280V, adjustable |
With load |
The output current is 1-20A, and the voltage is 110V-275V, adjustable |
Power factor PF |
under 10A is adjustable from 0.45~0.98 , above 10A is adjustable from 0.3~0.96 |
The power factor resolution |
0.02. |
Accuracy |
0.5 class, digital display |
Common load
Without load |
the voltage i s 50V-280V, adjustable |
With load |
The output current is 1-20 A, and the voltage is 110V-275V, adjustable |
Power factor PF |
under 10A is adjustable from 0.45~0.98 , above 10A is adjustable from 0.3~0.96 |
The power factor resolution |
0.01. |
Accuracy |
0.5 class, digital display |
Load put on/off ratio and proportion |
25% ON, 75% OFF |
Working mode |
Intermittent mode |
Load switching method |
panel switch to switch the on and off. |
Display and control |
7-inch touch screen display interface+PLC control |
Output routs load |
Three routs |
Protection functions |
With leakage, overload, overheating protection functions. |
|
Based on the different standard requirements to built nearly 30 kinds of commonly used parameters mode, the tester reserved 10 kinds of custom mode, it can based on your real need to setup |