• IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine
  • IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine
  • IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine
  • IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine
  • IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine
  • IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine

IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine

Warranty: 12 Months
Working Voltage: AC380V±5%, 50Hz
Gas Flow: 0-100m³/H
Maximum Gas Pressure: 3000PA
Air Flow: 5000m³/H
Maximum Air Pressure: 4000PA
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2018

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (30)

Basic Info.

Model NO.
SH5516A
Function
Fireproof Cables Fire Testing
Delivery
Within 10-40 Working Days After Order Confirmed
Shipment
Ocean or The Customer′s Requirement
Transport Package
Wooden Box
Specification
1000*800*1600 mm
Trademark
Sunho
Origin
China Mainland
HS Code
9031809090
Production Capacity
1500 Set Per Year

Product Description

IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine

1. Product Description

This test device is divided into two test zones according to the JIS A1304 standard, Japanese basic fire resistant requirements, IEC60331-12, IEC60331-31 requirements, Japanese standard wire and cable fireproof test furnace and IEC standard wire and cable fire resistance, ram impact test combustion chamber. The refractory furnace temperature increase program meets the temperature rise curve specified in JIS A1304. The test area is controlled by a main control cabinet and a PC, sharing the wire load and gas supply station. After the entire device on-line, the fire resistance performance of wire and cable can be tested.

2. Standards

JIS A1304, IEC60331

3. Technical Parameters
 
A: Japan standard wire and cable fire resistance test furnace
The test tunnel composed brick,steel structure and fireproof and heat insulation material
Furnace size height 1.4m X width 0.45m X depth about 1.2m
The largest sample size length about 800 X diameter 80mm.
Working voltage AC380V±5%, 50Hz
Gas flow 0-100m³/h
Maximum gas pressure 3000Pa
Air flow 5000m³/h
The maximum air pressure 4000Pa
Test temperature control Conforms to the temperature requirements of 3-11 in JIS1304
Furnace temperature ±15°C
Specimen internal temperature ±10°C
Timing range 0-300min
Timing accuracy ±1s
Temperature sensor The performance, number, and location of thermocouples in a furnace conform to the requirements of JIS A1304
B: IEC standard wire and cable fire-resistant, slamming test burning chamber
Test flame gas source propane gas or liquefied petroleum gas (user-supplied gas)
The burner is a propane gas torch with Venturi mixer nozzle length 500mm, width 15mm
There are three rows of staggered holes in the nozzle the hole diameter is 1.32mm, and the hole pitch is 3.2mm. The test stand is made according to IEC60331 Figure 1, Figure 2, Figure 3, Figure 4
Shock generating device Φ25 ± 5% thick round bar, length 600mm
The impact device hits at an angle 60°
  Impact time is automatically timed and automatic action is performed
  With dual flow meter and pressure regulation
Air flow meter range 0.5-5m³/ h
Gas flow range 0.1-1m³/ h
With a temperature measuring device the flame temperature is automatically adjusted according to the set value (830°C) during the test, including the flameout protection device
Test time 0-99min99s, can be set arbitrarily by PC
Intelligent detection function when the sample in the test process short circuit, automatic alarm and turn off the fire source
The size of the combustion chamber 3.5m X 3m X 3m with exhaust air outlet

C: specimen load and pressure resistant test system
Load cabinet test voltage three-phase AC600V-1500V; test current range: 0.1-1A, test current can be adjusted according to the standard requirements, but more than 2A protection (fuse or circuit breaker); sample loop can monitor up to 5 (L1, L2, L3, N, PE lines)
Withstand voltage test Withstanding voltage (kV): AC 0.6-1.5 adjustable; Breakdown current (mA): 1-100 can be set; Withstand voltage time: 1-99min99s can be set; Automatic boost, boost speed : 1500V/min
 
IEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing MachineIEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing MachineIEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing MachineIEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing MachineIEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing MachineIEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing MachineIEC60331 Small Furnace Method Reliable Fireproof Cables Fire Test/Testing Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.