Warranty: | 12 Months |
---|---|
Test Voltage: | 50 to 280V |
Test Current: | 0~20A |
Accuracy: | 0.5% Class +0.5% Full-Scale |
Power Factor Accuracy: | ±0.02 |
Working Mode: | Discontinuous Mode |
Customization: |
---|
Suppliers with verified business licenses
UL1054 Test/Testing Machine For Annex Power Load Counter
1. Product Description
Matching to the use with the mechanical movements test equipment (such as plugs and sockets life tester), for on and off capacity test, breaking capacity test, bend test and the normal operation test and so on.
Can provided to all types of electrical annex 1-20A, 0-280V and 0.3-0.96 power factor of resistance and susceptibility testing load.
Inductance can choose to input or disconnection.
The machine is made of high-grade aluminum structure,in simple ,generous in appearance.
Matching to the use with the mechanical movements test equipment(such as RH19401 plugs and sockets life tester),for on and off capacity test,breaking capacity test,bend test and the normal operation test and so on.
Using intelligent controller,easy to operate.Have 30 fix mode for user to set,preset current,power and power factor with inner resistance and inductance matrix by just one click.And 10 other customize mode for user to set their required test parameter.
Intelligent automatic fitting function:input the standard required test parameter,calculate the V,L,R value by intelligent computing;programmed the hardware of corresponding parameter to preset(no output at preset).Programmed output to the external connection terminal to the sample after regulate the parameter to the require value.Using resistance matrix and inductance matrix to replace manual regulation,varieties of test mode and experienced intelligent digital control system,simplify the operation,and reduce error possibilities and training cost.
2. Standards
IEC60884, IEC60669, IEC61058, UL1054
3. Technical Parameters
Power Supply | AC220V/50Hz |
Test Voltage | can continuously adjustable from 50 to 280V, voltage resolution is 0.1v. |
Test Current | Single route, Can continuously adjustable from 0~20A (Can choose the 30A/50A/100A),current resolution is 0.1A. |
Power factor PF |
Power factor cosj:above 10A 0.3-0.96,below 10A:0.45-0.96
|
Accuracy | 0.5% class +0.5% full-scale |
Power factor Accuracy | ±0.02 |
Digital Display | Digital displayed the voltage, current, power and power factor. |
Working Mode | Discontinuous mode |
Remark | The load is resistive load and inductive load |
The tester supplied the standard load for the plug and socket or the switch life test when they carry on the test. |
Suppliers with verified business licenses