Warranty: | 12 Months |
---|---|
Chamber Inner Dimension: | 4m³ |
Test Angle: | 0°, 20°, 45 Can Be Set |
Thermal Copper Block: | Length 19.14±0.02m, Diameter 9mm |
K Type Thermocouple: | Diameter Is 0.5m |
Temperature Resolution: | 1ºC |
Customization: |
---|
Suppliers with verified business licenses
Chamber inner dimension | 4m³ |
Gas source | Coal gas or liquefied petroleum gas ( good quality gas is recommended if possible). Burner inner diameter φ9.5±0.5mm,length 102mm, with air hole. Flame height can be set from 20mm to 175mm |
Test angle | 0°,20°,45 can be set |
Burning time and flame holding time | Can be set from 1s- 99min99s. It is automatic during test |
With gas flow meter and pressure regulation | |
Electric lighter |
Thermal copper block | Length 19.14±0.02m, diameter 9mm |
K type thermocouple | Diameter is 0.5m |
Temperature resolution | 1ºC |
Flame height gauge | locate the thermal copper block to the burner, height:55mm |
Timer: accuracy | 0.01s, can record the time thermal copper block use to rise from 100°C to 700°C, start to count when temperature reach 100°C, and stop automatically when reach 700°C |
Have a observation glass window. |
Suppliers with verified business licenses